Accuracy of cone-beam CT in detecting vertical root fractures in teeth with post-endodontic restorations: an in vitro study

Auteurs-es

  • Fernanda Chiguti Yamashita Universidade Estadual de Maringá Auteur
  • Amanda Lury Yamashita Universidade Estadual de Maringá Auteur
  • Irma Milena Menck Romanichen Universidade Estadual de Maringá Auteur
  • Elen de Souza Tolentino Universidade Estadual de Maringá Auteur
  • Sérgio Sábio Universidade Estadual de Maringá Auteur
  • Mariliani Chicarelli Universidade Estadual de Maringá Auteur
  • Lilian Cristina Vessoni Iwaki Universidade Estadual de Maringá Auteur

DOI :

https://doi.org/10.4025/actascihealthsci.v43i1.55832

Mots-clés :

diagnosis; tooth fracture; in vitro; diagnostic imaging

Résumé

The aim of this study was to evaluate the accuracy of cone-beam CT (CBCT) for the detection of artificially created vertical root fractures (VRF) in extracted teeth restored with metallic (MP) and fiberglass (FGP) posts. After root canal obturation, 60 extracted human premolars were scanned by using the highest-resolution settings of a CBCT unit. The prepared roots were randomly divided into three groups: group C (control group): non-restored and non- endodontically treated teeth (n = 20); group MP (n = 20); group FGP (n = 20). In all groups, 10 teeth were artificially fractured. Two external and independent observers blindly recorded the presence or absence of VRF. Sensitivity, specificity, accuracy, intra- and interobserver agreement were calculated. Kappa value for inter- and intraobserver agreement was 0.82 and 0.84 respectively, demonstrating good agreement. The highest values for sensitivity (0.80 - 0.90), specificity (1.00) and accuracy (0.90 - 0.95) were found in the control group. The teeth with FGP restoration presented the lowest sensitivity (0.30 - 0.50) and accuracy (0.60 - 0.65) values. Both examiners had a good performance in the diagnosis of fractures in teeth with MP, with accuracy ranging between 0.85 - 0.90. The presence of MP did not influence accuracy; however, the presence of FGP reduced the diagnostic capacity of CBCT.

Téléchargements

Les données de téléchargement ne sont pas encore disponible.

Téléchargements

Publié

2021-10-13

Numéro

Rubrique

Odontologia

Comment citer

Yamashita, F. C., Yamashita, A. L. ., Romanichen, I. M. M., Tolentino, E. de S. ., Sábio, S., Chicarelli , M. ., & Iwaki, L. C. V. (2021). Accuracy of cone-beam CT in detecting vertical root fractures in teeth with post-endodontic restorations: an in vitro study. Acta Scientiarum. Health Sciences, 43(1), e55832. https://doi.org/10.4025/actascihealthsci.v43i1.55832

Articles similaires

11-20 de 109

Vous pouvez également Lancer une recherche avancée d’articles similaires à cet article.

Articles les plus lus du,de la,des même-s auteur-e-s

1 2 > >>